Abstract
Introduction: Amniotic fluid is an important factor in the prediction of fetal survival. The aim of this research was to evaluate the effects of intravenous hydration of mothers on amniotic fluid volume and in turn on pregnancy outcomes. Methods: The current single blind controlled clinical trial was conducted on 20 pregnant mothers with amniotic fluid index of lower or equal to 5 cm and gestational age of 37-41 weeks. The subjects were divided into two groups of case and control through simple random sampling. Amniotic fluid index was measured in all participants. The case group received one liter of isotonic saline during 30 minutes by the bolus method. Reevaluations of amniotic fluid index in both groups were made 90 minutes after baseline measurement. Independent t-test and paired t-test were used to compare the two groups and mean amniotic fluid index before and after treatment, respectively. Results: Hydration of mothers significantly increased the amniotic fluid index in the case group (mean change: 1.5 cm; 95%CI:
0.46 - 2.64; P = 0.01). The mean change of amniotic fluid index in the control group did not significantly increase (P = 0.06). The elevation of amniotic fluid index in the hydration group (32%) was significantly higher than the control group (1%) (P = 0.03).
Conclusion: In this study intravenous hydration increased amniotic fluid index of mothers with term pregnancy and oligohydramnios. Since it caused no complications for the mother and the fetus, it can be used as an effective method in management of oligohydramnios.